Siemens patches MCP server flaws in Mendix Studio Pro
CISA advisory published 17 November 2026 says the low-code tool's agent connector listened beyond localhost and accepted cross-site requests.
By The Agentic Times ·

Siemens has fixed two vulnerabilities in the MCP Server component of its low-code development tool Mendix Studio Pro, according to an advisory published by the US Cybersecurity and Infrastructure Security Agency on 17 November 2026. The flaws, tracked as CVE-2026-112136 and CVE-2026-112137, could allow an attacker with network access to talk to the server directly, or trick a user's browser into issuing unauthorised requests. CISA said the result could be unauthorised data access, tool execution or system compromise. Siemens ProductCERT reported the issues to CISA.
MCP, the Model Context Protocol, is the interface that lets AI assistants call tools and read data from a local application. In Mendix Studio Pro the MCP Server runs on the developer's own machine and listens on port 7782.
The more serious issue, CVE-2026-112136, is a case of binding to an unrestricted IP address. The advisory says the MCP Server does not properly restrict its HTTP listener to the loopback interface, so it may be reachable from other systems on the network rather than only the local machine. CISA lists a CVSS v3.1 base score of 8.8, rated high.
The second issue, CVE-2026-112137, is a cross-site request forgery flaw. The MCP Server does not properly validate the Content-Type and Origin headers on incoming HTTP requests, the advisory says, so a malicious web page could cause a user's browser to send requests to the local server and carry out actions the user did not intend. That flaw carries a CVSS v3.1 base score of 5.4, rated medium.
Affected versions are Mendix Studio Pro 11 from V11.15.0 up to but not including V11.16.0, and Mendix Studio Pro 11.12 from V11.12.6 up to but not including V11.12.7. Both CVEs apply to both version ranges. Siemens has released fixed versions and recommends updating to V11.16.0 or later, or V11.12.7 or later.
For users who cannot patch immediately, Siemens suggests maintaining strict inbound firewall policies, such as Windows Defender Firewall, to block external traffic on port 7782. The advisory notes this is already the default on standard Windows installations. Where remote access is genuinely needed, Siemens recommends routing it through a secure, authenticated channel such as a VPN or SSH tunnel rather than opening direct inbound firewall rules.
To blunt the CSRF issue, the advisory suggests using modern Chromium- or WebKit-based browsers with Private Network Access protections turned on, or browser extensions such as uBlock Origin or NoScript that stop external websites from issuing fetch requests to localhost.
Siemens said that as a general measure it strongly recommends protecting network access to devices with appropriate mechanisms, and configuring environments according to its operational guidelines for industrial security. CISA repeated its standard advice to minimise network exposure for control system devices, keep them off the internet, and place control system networks and remote devices behind firewalls isolated from business networks.
The advisory lists Mendix Studio Pro as deployed worldwide, with critical manufacturing and energy named as the relevant critical infrastructure sectors. Siemens is headquartered in Germany. The advisory does not report any exploitation of either flaw.
Sources
- cisa.govhttps://cisa.gov/news-events/ics-advisories/icsa-26-321-05